Popxa willow leaf logoPOPXAInternational Trade Co., Ltd. Send OE List

MG4 battery-electric hatchbacks • MSP, XPOWER and Urban identified separately

MG4 Thermal, Cabin & Low-Voltage Parts

Prepare MG4 cabin-filter, cooling, refrigerant and ordinary low-voltage requests. Separate circuit identity and heat-pump equipment from controlled HV units.

cabin air filter, water pump, horn assembly assembly comparison
Assembly types shown for comparison. Confirm each component separately; these are not one interchangeable kit.

Separate cabin service from engine service

The service filter in an MG4 cabin request belongs to the HVAC tray. These BEVs do not call for combustion-engine intake, lubrication, ignition or fuel-delivery items. Identify the removed filter perimeter, thickness, airflow and media grade before selecting an earlier MSP or Urban cabin element.

Trace each fluid before matching a finned core

Coolant radiators, refrigerant condensers and cabin evaporators serve different circuits. Heat-pump equipment can change the accepted refrigerant arrangement. Retain hose or line joints and the exact platform cooling package; similar core dimensions do not establish function or interchange.

Identify ordinary pumps, valves and probes independently

A standalone low-voltage coolant pump needs its own circuit label, ports and electrical marking. Match routing valves and temperature probes to their real installed positions rather than a warning message. Complete integrated HV thermal modules and electric compressors/heaters need separately confirmed supply, not a generic pump or exchanger quotation.

Keep cabin airflow and control contents explicit

The blower wheel, motor, speed controller and filter tray have different interfaces. Retain the steering-market case and sockets before agreeing a controller with or without a motor. A front cooling fan is not a cabin blower, and similar fins on two electronic modules do not establish matching control functions.

Do not confuse ordinary electrical loads with the traction system

A horn or door switch pack needs voltage, socket and bracket or trim-seat confirmation. A horn is not a pedestrian-alert speaker; a window switch is not a regulator motor. HV batteries, inverters, traction drives, charging inlets and converters require separate business, transport and configuration confirmation.

Related assembly decisions

On an identified MSP front end, the active grille shutter regulates the opening ahead of the radiator; the radiator cooling fan supplies airflow separately.

A passive bumper insert or shared core size cannot choose the shutter frame and actuator.

The cabin air filter seals the HVAC intake tray, the blower motor moves cabin air and the blower control module controls its speed.

Keep the actual case and electrical interfaces with all three requests rather than using an engine-filter specification.

The radiator cooling fan has to align with the accepted radiator and A/C condenser package.

Similar fins do not make the coolant and refrigerant exchangers interchangeable; preserve their different pipe joints and mounting layers.

Trace the low-voltage water pump, coolant reservoir and coolant control valve within the same identified coolant loop.

Do not assemble a battery or drive-unit cooling set from visually similar components belonging to different circuits.

Assemblies to identify separately

AssemblyApplication boundarySelection record
Cabin Air FilterExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeTray dimensions, airflow direction, frame and media
RadiatorExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeCore, hose ports, gearbox cooler fittings and mounts
Radiator Cooling FanExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeShroud, motor/controller, socket and mounting
Water PumpIdentified standalone low-voltage electric coolant pump and exact loop only; integrated HV modules excludedCircuit, drive, housing, impeller and ports
Coolant ReservoirExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeBottle, cap rating, hose map, sensor and brackets
A/C CondenserExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeCore, connection blocks, receiver and mounting
A/C EvaporatorExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeCore outline, tube routing, block and seal faces
Blower MotorExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeWheel depth, rotation, flange and socket
Blower Control ModuleExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeLabel, heat sink, sockets and mounting
A/C Pressure SensorExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeMarking, thread/port, socket and signal function
Coolant Control ValveConfirmed separately supplied low-voltage coolant-routing valve only; integrated HV thermal modules excludedActual low-voltage valve, port routing, actuator, connector and circuit label
Coolant Temperature SensorExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeCoolant-loop position, sensing range, seat, seal and electrical signal
Active Grille ShutterConfirmed MSP/EH32 motorized airflow shutter only; no assumed Urban application or decorative-grille equivalenceConfirmed MSP airflow-control frame, louvres, motor, mounting and connector
Horn AssemblyOrdinary audible horn only; acoustic vehicle alerting speaker and safety-control modules are separateLow-voltage horn, tone, connector, bracket and installed position
Power Window SwitchExact MSP RWD, XPOWER or Urban assembly identity, chassis/circuit and installed interfaces; no automatic cross-platform interchangeDoor, side, switch panel, connector, one-touch and lockout functions

Continue the identified order

Use the MG4 system directory for the remaining assemblies and the parts-list quotation guide for quantities and destination. Keep the platform and drive record with each component.

Auto parts inquiry

Send the vehicle and part evidence.

Include brand, full model, year, engine or EV drivetrain, OE/material code, quantity, destination and packing request. You can attach a list or old-part photos.

* Provide at least one contact method: Email, WhatsApp or WeChat.

Optional: spreadsheet, PDF, image or ZIP package (up to 25 MB each and 60 MB total).